 AC-DC
60 Watts SDS60 Series
* * * * * * *
xppower.com
Single, Dual, Triple & Quad Outputs Output Voltages from 3.3 V to 48 V Non-standard Outputs Available Universal AC Input Low Profile - 1.2" (30.5 mm) Fits 1U Applications Up to 88% Efficiency
Specification
Input
Input Voltage Input Frequency Input Current * 90-264 VAC (120-370 VDC) * 47-63 Hz * 1.6 A at 115 VAC 1.0 A at 230 VAC Inrush Current * <15 A at 115 VAC <30 A at 230 VAC Earth Leakage Current * <0.30 mA at 115 VAC <0.75 mA at 230 VAC Input Protection * 2 A/250 VAC internal fuse
General
Efficiency Isolation * 80% typ, 88% max, 230 VAC 100% load * 3000 VAC Input to Output 1500 VAC Input to Ground 500 VAC Output to Ground * 60 kHz typical * 3.5 W/In3 * Green DC OK LED * >100 kHrs per MIL-HDBK-217F
Switching Frequency Power Density Signals MTBF
Environmental Output
Output Voltage Output Voltage Trim Initial Set Accuracy * See table * 10% on V1 only (see note 4) * Single output models: 1% Multi-output models: 5% Minimum Load * 10% required on V1 & V2 of multi-output models to maintain regulation, unit will start up with no load Start Up Delay * 1 s typical Hold Up Time * 12 ms min at 110 VAC, 100% load Line Regulation * 1% from low line to high line Load Regulation * 5% max all models, 10% with no load on V1 - see table Transient Response * 4% max deviation, recovery to within 1% in 4 ms for a 50% load change Ripple & Noise * 1% pk-pk typical, 20 MHz BW Overvoltage Protection * 112-132%, recycle input to reset Overload Protection * All outputs 110-150% with auto recovery Short Circuit Protection * Trip & restart (Hiccup mode), auto recovery Temperature * 0.04%/C Coefficient Operating Temperature * 0 C to +70 C, derate linearly from 100% load at +40 C to 50% load at +70 C Cooling * Convection-cooled Operating Humidity * 5-95% RH, non-condensing Storage Temperature * -40 C to +85 C
EMC & Safety
Emissions Harmonic Currents Voltage Flicker ESD Immunity Radiated Immunity EFT/Burst Surge Conducted Immunity Magnetic Field Dips & Interruptions * * * * * * * * * * EN55022, FCC Part 15, level B conducted EN61000-3-2 EN61000-3-3 EN61000-4-2, level 2 Perf Criteria A EN61000-4-3, 3 V/m Perf Criteria A EN61000-4-4, level 2 Perf Criteria A EN61000-4-5, level 3 Perf Criteria A EN61000-4-6, 3 V Perf Criteria A EN61000-4-8, 1 A/m Perf Criteria A EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms Perf Criteria A, B, B * EN60950-1, UL60950-1, CSA60950-1 per cUL, CE Mark LVD
Safety Approvals
AC-DC
Models and Ratings
Maximum Output Power 50 W 55 W 60 W 63 W 63 W 63 W 63 W 63 W 63 W 63 W 63 W Maximum Output Power 63.0 W 48.1 W 63.0 W 63.0 W 63.0 W 53.5 W 53.5 W 63.0 W 63.0 W 63.0 W 63.0 W 63.0 W 63.0 W 63.0 W 63.0 W 63.0 W 63.0 W 63.0 W 63.0 W 59.3 W Output Voltage 3.3 5.0 7.0 9.0 12.0 15.0 19.0 24.0 30.0 36.0 48.0 V V V V V V V V V V V Output Current 15.1 11.0 8.6 7.0 5.2 4.2 3.3 2.6 2.1 1.7 1.3 A A A A A A A A A A A Output(2,3,4) V2 12.0 5.0 12.0 12.0 12.0 5.0 5.0 12.0 12.0 15.0 24.0 24.0 24.0 12.0 12.0 12.0 12.0 12.0 15.0 24.0 V/3.0 V/5.0 V/3.0 V/3.0 V/3.0 V/5.0 V/5.0 V/3.0 V/3.0 V/3.0 V/2.0 V/2.0 V/2.0 V/3.0 V/3.0 V/3.0 V/3.0 V/3.0 V/3.0 V/1.8 A A A A A A A A A A A A A A A A A A A A Factory-Set Voltage Range(1) 3.0-5.0 5.0-6.0 6.0-8.0 8.0-11.0 11.0-13.0 13.0-16.0 16.0-21.0 21.0-27.0 27.0-33.0 33.0-40.0 40.0-50.0 VDC VDC VDC VDC VDC VDC VDC VDC VDC VDC VDC Output(3) V3 Current Range 16.6-10.0 11.0-9.1 10.0-7.5 7.8-5.7 5.7-4.8 4.8-3.9 3.9-3.0 3.0-2.3 2.3-1.9 1.9-1.5 1.5-1.2 A A A A A A A A A A A Output(3) V4 Total Regulation 5% 5% 4% 3% 3% 3% 3% 2% 2% 2% 2%
SDS60
Model Number(5,6) SDS60US03 SDS60US05 SDS60US07 SDS60US09 SDS60US12 SDS60US15 SDS60US19 SDS60US24 SDS60US30 SDS60US36 SDS60US48 Model Number(5,6) SDS60UD01 SDS60UD04 SDS60UT00 SDS60UT01 SDS60UT02 SDS60UT03 SDS60UT04 SDS60UT05 SDS60UT06 SDS60UT07 SDS60UT08 SDS60UT09 SDS60UT10 SDS60UQ00 SDS60UQ01 SDS60UQ02 SDS60UQ03 SDS60UQ04 SDS60UQ05 SDS60UQ06
Output(2,3,4) V1 5.0 3.3 3.3 3.3 3.3 3.3 3.3 5.0 5.0 5.0 5.0 5.0 5.0 3.3 3.3 5.0 5.0 5.0 5.0 5.0 V/7.0 V/7.0 V/6.0 V/6.0 V/6.0 V/5.0 V/5.0 V/6.0 V/6.0 V/6.0 V/6.0 V/6.0 V/6.0 V/6.0 V/6.0 V/6.0 V/6.0 V/6.0 V/6.0 V/6.0 A A A A A A A A A A A A A A A A A A A A
-12.0 -5.0 +5.0 +12.0 -12.0 -12.0 -5.0 -15.0 -24.0 -12.0 +12.0 -12.0 -12.0 -12.0 -12.0 -12.0 -15.0 -15.0
V/0.8 V/0.8 V/0.8 V/1.0 V/1.0 V/0.8 V/0.8 V/0.8 V/0.5 V/0.8 V/0.8 V/0.8 V/0.8 V/0.8 V/0.8 V/0.8 V/0.8 V/0.1
A A A A A A A A A A A A A A A A A A
-5.0 +5.0 -5.0 +24.0 -24.0 -5.0 +12.0
V/0.8 V/0.8 V/0.8 V/0.8 V/0.8 V/0.8 V/0.8
A A A A A A A
Notes
1. 2. 3. 4. 5. 6. If an output voltage within the factory-set voltage range is required, a model number will be allocated at the time of order. 10% minimum load required on V1 & V2 of multi-output units to maintain regulation of 5%. Regulation increases to 10% with no load. Other output combinations are available - contact sales for more information. On multi-output units V2 tracks V1, if V1 is adjusted by 5%, V2 changes by 5%. For optional U-bracket, add suffix `B' to model number. For optional cover, add suffix `-C' to model number (only available with `B' version). For optional 2 pin AC input use suffix `C' (open frame) or change `B' suffix to `D' (U bracket)
Available from Farnell. See pages 204-206.
Mechanical Details
All dimensions are in inches (mm) Weight: 0.52 lbs (240 g) approx
PIN CONNECTIONS Dual Output Triple Output Output 2 Output 2 Output 1 Output 1 Output 1 Output 1 Common Common Common Common N/C Output 3
0.157 (4.0) DIA MOUNTING HOLE (4PL.)
0.22 (5.6)
ADJ DC OK LED 2.55 (64.8) 3.00 (76.2) P2 DC OUTPUT
1
AC INPUT P1 L N G
6 (multi output only) 7 8
Pin 1 2 3 4 5 6 7 8
Single Output Output 1 Output 1 Output 1 Return Return Return
Quad Output Output 2 Output 1 Output 1 Common Common Output 3 Output 4 Output 4
4.56 (115.8) 5.00 (127.0)
0.22 (5.6)
0.12 (3.0) max
Tolerance: 0.02 (0.5)
Notes: 1. Input connector mates with Molex housing 09-50-3051 and Molex 2878 series crimp terminal. 2. Output connector mates with Molex housing 09-50-3061 or 9-50-3081 and Molex 2878 series crimp terminal. 3. For optional cover kit order part number SDS60 COVER KIT, to receive unit with cover fitted add suffix `-C' to model number. Cover size: 5.46 x 3.55 x 1.55 (140 x 91 x 39.7mm). 4. For mating connectors and cable harness order part numbers: SDS60 CON KIT - Single, dual and triple output models SDS60Q CON KIT - Quad output models SDS60 LOOM KIT - Single output models cable harness SDS60DT LOOM KT - Dual and triple output models cable harness SDS60Q LOOM KIT - Quad output models cable harness
1.20 (30.5)
17-Apr-07


▲Up To Search▲   

 
Price & Availability of SDS60UD01

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X